China Exploration Instrument Online Market

High quality, Best service,Reasonable price.

Home ProductsEnvironmental Test Chambers

Environmental Absolute Reliability Thermal Shock Test Chamber GB/T 2443.1-2001

Environmental Absolute Reliability Thermal Shock Test Chamber GB/T 2443.1-2001

  • Environmental Absolute Reliability Thermal Shock Test Chamber GB/T 2443.1-2001
  • Environmental Absolute Reliability Thermal Shock Test Chamber GB/T 2443.1-2001
  • Environmental Absolute Reliability Thermal Shock Test Chamber GB/T 2443.1-2001
Environmental Absolute Reliability Thermal Shock Test Chamber GB/T 2443.1-2001
Product Details:
Place of Origin: China
Brand Name: KOMEG
Certification: CE,,ISO
Model Number: KTS-100A
Payment & Shipping Terms:
Minimum Order Quantity: 1 units
Price: Negotiable
Packaging Details: Packed in carton firstly, and then reinforced with plywood case for outer packing
Delivery Time: 20 work days
Supply Ability: 20 sets per month
Contact Now
Detailed Product Description
Chamber Volume Size: 27L To 480L Low Temp. Chamber: -55℃~-10℃
High Temp. Chamber: +60℃~+200℃ Pre-heat Time: +60℃~+200℃ ,Within 20 Min
Shock Range: -55ºC~+150ºC Transition Time: ≤15S
Recovery Time: 5min Temperature Change Rate: 15 To 50 ºC/min
High Light:

environmental testing chamber

,

Environmental Test cabinet

Standard Environmental Thermal Shock Test Chamber Tested for Absolute Reliability

 

Applications

Thermal shock chamber is a chamber which use method of environmental testing that subjects a product to alternating extremes of high and low temperatures. The application of rapid temperature cycling is the most effective manner of creating premature failures of products in the production phase. We can simulate all natural temperatures which, when considering the fields of aviation and aerospace, range between -80 °C and +220 °C. It is used to test the capability of material structure or composite material to withstand the continuous environmental changes between extremely high temperature and low temperature during a short period.

 

Features

 

1) Test samples don't move. Thermal shork chamber in each zone for peak demand of heating and cooling.

2) Horizontal airflow design assures uniform results

3) Extremely compact systems with a vertically sliding door for added space savings

4) Utilizes the latest refrigeration technology: electronic expansion valve and high-tech compressor. Provides extra thermal energy to efficiently meet the MIL-STD 883 requirements.

5) Temperature recorder provides 24 hour part temperature recording as the load travels from zone to zone. 

6) Using touch-control graph control as operation interface, easy to operate.

7) The system can be used for automatic Circulation Shock or manual selective shock, capable of setting two zones or three zones shocks as well as cold and thermal shock start-up.

8) Custom-made and optional accessories available.

 

Standards Implement and Met

GB/T 2443.1-2001 Test A: Low temp. Test;
GB/T 2443.2-2001 Test B: Low temp. Test;
GB/T 2443.22-2002 Test N: Low temp. Test;
GJB 150.3-1986 High Temp. Test;
GJB 150.4-1986 Low temp. Test;
GJB 150.5-1986 Temp. Impact Test;
(Load refer to 5.5.5 no active load)

 

Working Principle

There are three chambers used to perform thermal shock testing, high-temperature chamber, low-temperature chamber and test chamber. Sample is placed in the test chamber, more extreme temperature than test temperature can be set in high-temperature chamber and low-temperature chamber. When doing low temperature testing, cold chamber door open, and low-temperature chamber working together with test chamber.

When converted into high-temperature test, cold chamber door closed, hot chamber door are opened, and test chamber working together with high-temperature chamber. Conversion of mechanical action (transferring from high temperature to low temperature or low temperature to high temperature) can be completed in less than 1second, and the temperature can be quickly stabilized.

During the whole test, test sample is no need to be moved, and without any human intervention.

Environmental Absolute Reliability Thermal Shock Test Chamber GB/T 2443.1-2001 0

Environmental Absolute Reliability Thermal Shock Test Chamber GB/T 2443.1-2001 1

Environmental Absolute Reliability Thermal Shock Test Chamber GB/T 2443.1-2001 2

 

Specifications

Model

 

KTS-A Series

72A

100A

150A

200A

252A

300A

480A

Inside size(mm)

W

450

500

600

670

700

800

800

H

400

450

500

600

600

600

800

D

400

450

500

500

600

650

750

Outside size(mm)

W

1490

1540

1640

1720

1750

1850

1850

H

1790

1840

1890

2000

2000

2000

2200

D

1600

1700

1830

1850

1930

1980

2500

Test weight

5

10

12

15

18

20

20

Low Temp Chamber

 -55ºC~-10ºC, Pre cooling time: ≤ 60 min from +20ºCto-55ºC

Test Chamber

 -40ºC~+150ºC

High Temp Chamber

 +60ºC~+200ºC ,Within 20 min, Pre-heating time

Transition time

≤15S

Recovery time

High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample

Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample

≤ 5 min

Ambient Temp.

+5ºC~+35ºC

Power

AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires

Contact Details
China Exploration Instrument Online Market

Contact Person: Mr. Roni

Fax: 86--6666-7777

Send your inquiry directly to us (0 / 3000)

Other Products