China Exploration Instrument Online Market
High quality, Best service,Reasonable price.
Place of Origin: | China |
Brand Name: | Haida |
Certification: | CE,,ISO |
Model Number: | HD-E703 |
Minimum Order Quantity: | 1 |
---|---|
Price: | Negotiation |
Packaging Details: | each set protected with resin fiber and PP film, then put into Strong wooden case with operation man |
Delivery Time: | 20 days after order confirmed |
Payment Terms: | L/C, T/T, D/A, D/P, Western Union, MoneyGram |
Supply Ability: | 300 Sets per Month |
Usage: | High And Low Temperature Thermal Shock Test Chamber | High Temp. Exposure Range*1: | +60~ To +200°C |
---|---|---|---|
Low Temp. Exposure Range*1: | -65to 0 °C | Temp. Fluctuation *2: | ±1.8°C |
Pre-heat Upper Limit: | +200°C | Temp. Heat Up Time*3: | Ambient Temp. To +200°C Within 30min |
Pre-cool Lower Limit: | -65°C | Temp. Pull Down Time*3: | Ambient Temp. To -65°C Within 70min |
Temp. Recovery Time: | Within 10 Min. | External Material: | Cold-rolled Rust-proofed Steel Plate |
Test Area Material: | SUS304 Stainless Steel | Cooler: | Stainless Steel Welded Plate Heat Exchanger |
Air Circulator: | Sirocco Fan | Damper Driving Unit: | Air Cylinder |
Allowable Ambient Conditions: | +5~30°C | Power Supply: | AC380V, 50/60Hz, Three Phase , 30A |
Cooling Water Supply Pressure*6: | 02~0.4Mpa | Cooling Water Supply Rate*6: | 8m³ /h |
Operating Cooling Water Temp. Range: | +18 To 23 °C | Noise Level: | 70 DB Or Lower |
Use: | Thermal Shock Chamber | ||
Highlight: | Environmental Testing Equipment |
Safety Low High Temperature Testing Thermal Shock Tester Customized
1. Description:
Three-Zone High-Low Temperature Thermal Shock Environmental Test Chamber occurs when a thermal gradient causes different parts of an object to expand by different amounts. This differential expansion can be understood in terms of stress or of strain, equivalently. At some point, this stress can exceed the strength of the material, causing a crack to form. If nothing stops this crack from propagating through the material, it will cause the object's structure to fail.
2.the air conditioning system
. the air control: forced ventilation circulation, balance thermostat method (BTC). This method not only refers to the case of the cooling system for continuous operation, the control system according to the temperature set point of the heater to control the output of the results by automatically calculating PID output, and ultimately achieve a dynamic equilibrium.
. the air circulating means: built between the air circulation fan duct and the long axis of stainless steel, the use of energy efficient refrigerators and regulation system, by effective and efficient heat exchange ventilator, to achieve the purpose of the temperature change. By adjustable air outlet adjusting bolt, thereby significantly improving the chamber temperature uniformity;
. the air cooling method: multi-stage diaphragm air heat exchanger.
. the air heating: Watkins quality nickel chrome electric heater.
3. Specifications of Three-Zone High-Low Temperature Thermal Shock Test Chamber:
System |
Two-zone test by means of damper switching |
|||||||
Three-zone chamber |
||||||||
Model |
HD-E703-50A/HD-E703-50W |
HD-E703-100A/HD-E703-100W |
Customized |
|||||
Performance |
Test area |
High temp. exposure range*1 |
+60~ to +200°C |
|||||
Low temp. exposure range*1 |
-65to 0 °C |
|||||||
Temp. fluctuation *2 |
±1.8°C |
|||||||
Hot chamber |
Pre-heat upper limit |
+200°C |
||||||
Temp. heat up time*3 |
Ambient temp. to +200°C within 30min |
|||||||
Cold chamber |
Pre-cool lower limit |
-65°C |
||||||
Temp. pull down time*3 |
Ambient temp. to -65°C within 70min |
|||||||
Temp. recovery (2-zone) |
Recovery conditions |
Two-zone: High temp. exposure +125°C 30 min, Low temp. exposure -40°C 30 min; Specimen 6.5 kg (specimen basket 1.5kg) |
||||||
Temp. recovery time |
Within 10 min. |
|||||||
Construction |
External material |
Cold-rolled rust-proofed steel plate |
||||||
Test area material |
SUS304 stainless steel |
|||||||
Door*4 |
Manually operated door with unlock button |
|||||||
Heater |
Strip wire heater |
|||||||
Refrigeration unit |
System*5 |
Mechanical cascade refrigeration system |
||||||
Compressor |
Hermetically sealed scroll compressor |
|||||||
Expansion mechanism |
Electronic expansion valve |
|||||||
Refrigerant |
High temp side:R404A, Low temp side R23 |
|||||||
Cooler |
Stainless steel welded plate heat exchanger |
|||||||
Air circulator |
Sirocco fan |
|||||||
Damper driving unit |
Air cylinder |
|||||||
Fittings |
Cable port with diameter 100mm on the left side (right side and tailor made diameter size are available as options), specimen power supply control terminal |
|||||||
Inside dimensions (W x H x D) |
350 x 400 x 350 |
500 x 450 x 450 |
Customized |
|||||
Test area capacity |
50L |
100L |
Customized |
|||||
Test area load |
5 kg |
10 kg |
Customized |
|||||
Outside dimensions (W x H x D) |
1230 x 1830 x 1270 |
1380 x 1980 x 1370 |
Customized |
|||||
Weight |
800kg |
1100kg |
N/A |
|||||
Utility requirements
|
Allowable ambient conditions |
+5~30°C |
||||||
Power supply |
AC380V, 50/60Hz, three phase , 30A |
|||||||
Cooling water supply pressure*6 |
02~0.4Mpa |
|||||||
Cooling water supply rate*6 |
8m³ /h |
|||||||
Operating cooling water temp. range |
+18 to 23 °C |
|||||||
Noise Level |
70 dB or lower |
5.Notes
. If the high-temp exposure range lower limit + 60°C is required or the low temp exposure range lower limit -60°C, please select the “ambient-temperature exposure” option
. If the temp fluctuation need to below ±1.8°C please select the “Low temp fluctuation package”
. Temperature heat-up/pull down time are applicable only during independent chamber operation
. If the automatically operated sliding door required, please select the “Automatically door package”
. Air-cooled condenser / Water-cooled condenser both available
. Apply on water-cooled condenser only
6. Safety Devices of Three-Zone High-Low Temperature Thermal Shock Test Chamber:
. Hot chamber overheat protection switch
. Cold chamber overheat protection switch
. Air circulator overload alarm
. Refrigerator high/low pressure protector
. Compressor temperature switch
. Air pressure switch
. Fuse
. Water suspension relay ( water-cooled specification only)
. Compressor circuit breaker
. Heater circuit breaker
. Test area overheat/overcool protector
. Air purge valve
7.Control
(Color LCD interactive touch-screen system)
Operation and settings simplified by the use of a touch-screen LCD display (instructions displayed on-screen). At-aglance confirmation of test patterns, test area temperatures, temperature cycles, and trend graph displays.
Setting |
Interactive key input by touch panel |
Display |
LCD (5.7 inches) |
Temperature control function |
Test area: exposure temp. Hot chamber: pre-heating temp. Cold chamber: pre-cooling temp. |
PID control |
|
Preset temperature range |
High temperature: 60 to200’C Low temperature: -78 to 0’C |
Setting resolution |
1’C |
Input |
Thermocouple type T (Copper/Copper-Nickel) |
Setting and indication ranges |
Preset time: 0 min. to 99 hours and 59 min. Preset cycle: 1 to 9,999 cycles |
Accessory function |
Timer preset Overheat/ overcool protection Power failure/ recovery selection Temperature recovery time setting Program memory Automatic power shut-off Programmed time display Test completion mode selection Trend graph Alarm history display Sensor calibration RS-232/ USB communication |
8.Thermal Shock Chambers maintenance actions
. a reasonable choice of installation location to install measures: dry, non-drip of rain and snow place.
. inspection measures qualified by hand daily for insulation materials is broken steam pipe is blocked for technical confirmation and disposal technology.
. the alarm can be installed as conditional steam leak or power-off state of alarm sound and light small device to facilitate the holding of risk freezing measures discovery and timely remediation.
. instrument maintenance inspection measures by the area responsible for regular inspection by a predetermined inspection route. To check the insulation inspection of pipeline valve is normal, the incubator is normal, hydrophobic means is normal, thermal insulation material packaging is intact, electric heating power supply and other components is normal.
Simulation Animatronic Customer Triceratops are covered with air bubble film before put them into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc.
If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-conference. If customers require on-site service, the transport and travel expense shall be borne by customer.
. Pre-service
24 Hours online service for your consult.
Help choose right model,and a series of service,person,advise.
. Middle service
--Give you best offer
--Provide discount for many sets order
--Do customer's request:
--Choose payment term you convienent.
--Promptly production and delivery,inform you in time.
--Can provide invoice value as you like to decrease your tax.
. After sale service
--1 year warranty service and all life maintenance.
--Technical Egineer are avalible for oversea trainning.
--Free change for some parts
--Remote control technical consult
--Free installation DVD
--Maintenance plan
. Commitment:
We will sign a letter of commitment while we sign the contract, which will improve your confidence to us.
. Good Packaging:
Good Packaging: Simulation Animatronic Customer Triceratops are covered with air bubble film before put them into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc.
Why choose us?
1. Considerate Service Different countries plugs, manually change the-voltage from 110V to 220V, insurance indicator.
2.Excellent After sale Service:
18 months warranty. Besides, we can help you to repair your problem controller freely, even it's not from our factory. What you need to do is to send us the controller.
3.Commitment:
We will sign a letter of commitment while we sign the contract, which will improve your confidence to us.
4.Good Packaging:
Simulation Animatronic Customer Triceratops are covered with air bubble film before put them into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc.
How to Contact Us?
Please Send your inquiry Details in the below for our quotation,Click "Send" Now!
Contact Person: Mr. Roni
Fax: 86--6666-7777